Water quality affects the stability of production processes, equipment resource, and enterprise costs. Sand and suspended substances clog pipelines, hardness salts form scale, and high mineralization can violate technological requirements.
For water purification, methods such as mechanical and multimedia filtration and reverse osmosis are used. These methods serve different purposes and are often combined in one system. Let's explore their capabilities, limitations, and application features.
What water purification methods are used in enterprises
Three main technologies are used in industrial water treatment:
- Mechanical filtration — traps sand, rust, sludge, and other solid particles.
- Multimedia filtration — reduces turbidity and concentration of small suspended solids.
- Reverse osmosis — removes most dissolved salts, reducing hardness and total mineralization.
The choice depends on the composition of the source water and the specific production requirements.
Why water filtration is built in multiple stages
Multistage water filtration ensures the sequential removal of various contaminants. The mechanical filter traps large particles, the multimedia one cleans the water from smaller suspended substances, while the osmosis membrane removes dissolved salts.
This scheme reduces the load on the equipment, the risk of membrane clogging, and maintenance costs. At the same time, the composition of the water filtration system is determined by water analysis: not every enterprise needs all three stages.
Mechanical Water Filtration: What It Traps and Where Its Limits Are
Mechanical water filtration is designed to remove insoluble particles. Depending on the type of filter, the fineness of purification can range from units to hundreds of micrometers.
The main limitation: mechanical filters do not reduce hardness and mineralization, as dissolved salts of calcium, magnesium, and other elements pass freely through filtering materials.
Mesh, cartridge, and self-cleaning filters
- Mesh — mainly traps particles ranging from 50-500 micrometers, providing coarse filtration.
- Cartridge — works with finer impurities, typical filtration fineness is 1-20 micrometers.
- Self-cleaning — automatically removes accumulated contaminants without regular replacement of the filtering element. The filtration fineness is usually from 40 to 200 micrometers.
Cartridge filters require periodic replacement of elements, but usually do not create permanent water losses. Self-cleaning systems use water to clean the mesh, thereby reducing material costs.
For preliminary water treatment, mechanical filters for water are selected based on performance, purification fineness, and contamination characteristics.
Multimedia Filtration: When One Mechanical Stage Is Not Enough
If water contains many small suspended particles, cartridges clog quickly. In such cases, multimedia filtration may be a more effective solution — passing water through several layers of granular media.
This technology ensures reduced turbidity, trapping particles of sludge, clay, and insoluble iron compounds. The typical filtration fineness is approximately 10-50 micrometers depending on the design of the filter and media.
For large volumes of water consumption, multimedia filters for enterprises help stabilize the quality of pre-treated water and protect subsequent stages of water treatment.
Layers of media and what each one removes
In multimedia filters, the following can be used:
- Anthracite — traps larger suspended particles.
- Quartz sand — removes finer impurities.
- Garnet media — provides additional trapping of small suspended solids.
- Gravel — supports the filtration layers.
A standard multimedia system does not remove dissolved salts and divalent iron. For the latter, pre-oxidation or a special deironing technology is needed.
Backwashing instead of replacing cartridges
Contaminants from the media are removed by a reverse flow of water, which is discharged into the drainage. This allows for repeated use of filtering materials.
Operating costs include backwash water, electricity, and periodic maintenance. Water losses typically constitute a certain fraction of the total volume but depend on the frequency and duration of backwashes.
Reverse Osmosis: Purification from Dissolved Salts
Reverse osmosis is used when there is a need to reduce hardness and total mineralization of water. Under pressure, water passes through a semi-permeable membrane that retains most dissolved salts.
The typical salt rejection level is approximately 98-99.8%, depending on the membrane, water composition, and operating parameters.
Two streams are formed in the process: purified water (permeate) and concentrate with a higher salt content. With a typical permeate yield of 50-75%, about 25-50% of the input water is discharged as concentrate.
For industrial use, FLOWIX reverse osmosis systems are available, selected based on performance and required water quality.
Why the membrane does not work without pre-filtration
Suspended particles, colloids, iron compounds, and salt deposits contaminate the membrane surface. Without proper water preparation, its performance quickly decreases, and the frequency of backwashes increases.
Therefore, before osmosis, mechanical and, if needed, multimedia filtration, protective cartridges, softening, or dosing anti-scalant are applied. If free chlorine is present, its removal is required before sensitive membranes.
Operation requires electricity, reagents, periodic chemical cleaning, and membrane replacement.
| Method | What It Removes | Degree of Purification | Maintenance | Water Losses | Where It Is Used |
| Mechanical Filtration | Sand, rust, solid particles | Approximately 1-500 micrometers | Cartridge replacement or backwashing | None or periodic | Preliminary purification, equipment protection |
| Multimedia Filtration | Suspended solids, turbidity, insoluble iron | Typically 10-50 micrometers | Backwashing | Periodic, depends on mode | Industry, agriculture, pre-treatment before osmosis |
| Reverse Osmosis | Dissolved salts, hardness ions | 98-99.8% salt rejection | Backwashing and membrane replacement | Approximately 25-50% in concentrate | Boiler houses, food production, car washes |
The given values are typical guidelines. Actual efficiency and water losses depend on the design and operating mode of the equipment.
In terms of operational costs, mechanical filters are usually the simplest, multimedia require water for backwashing, and osmosis has higher costs for electricity, reagents, and membrane maintenance.
When Which Method Is Needed: Choice Based on Water Analysis and Task
Determining which water purification methods are needed for an enterprise is aided by laboratory research. More about its significance can be found in the material on water analysis before selecting a purification system.
- Turbidity — high values indicate the need for mechanical or multimedia filtration.
- Iron — at elevated concentrations, its form and the need for deironing are determined.
- Hardness — indicates the need for softening or osmosis if mineralization also needs to be reduced.
- Total mineralization (TDS) — helps assess the feasibility of using reverse osmosis.
Additionally, pH, conductivity, organic impurities, system performance, and technological process requirements are taken into account.
Typical Schemes for Boiler Houses, Food Production, Car Washes, and Agricultural Enterprises
| Object | Typical Scheme |
| Boiler House | Mechanical filtration → softening or osmosis depending on the boiler's requirements |
| Food Production | Mechanical → multimedia filtration → osmosis if needed → disinfection |
| Car Wash | Mechanical filtration → softening or osmosis for final rinse |
| Agricultural Enterprise | Mechanical → multimedia filtration → additional purification according to water purpose |
The schemes are indicative and may be supplemented with deironing, sorption purification, disinfection, or other stages.
Mechanical and multimedia filtration protect equipment from insoluble contaminants, while reverse osmosis provides reduced mineralization. An optimal system combines the necessary water purification methods according to the results of water analysis.
Flowix water treatment systems for business are developed considering technical requirements of the enterprise and parameters of the source water. Specialists from Invent Group will help determine the necessary purification stages, calculate performance, and select equipment.