Chlorides in water are one of the reasons for premature destruction of metal equipment in food and chemical industries. Even corrosion-resistant stainless steel can lose its protective properties under the influence of chloride ions. To reduce risks for pipelines, heat exchangers, and membrane systems, it is necessary to control the chemical composition of water and select Flowix water treatment equipment correctly.
Sources of Chlorides in Tap and Well Water
Chlorides are salts of hydrochloric acid that dissociate in water to form chloride ions Cl⁻. They can come from natural minerals, soil, marine deposits, and anthropogenic sources.
In tap water, their concentration depends on the composition of the source water and the peculiarities of water treatment. In wells, the chloride content can be elevated due to natural mineralization of the aquifer or pollution effects. Additional sources at enterprises can include technological solutions, wash waters, and leaks of salt mixtures.
For the industry, it is important to determine not only the total mineralization but also the content of chlorides in the water separately. An identical level of dissolved salts does not guarantee an identical corrosion risk since the effect depends on the composition of ions, temperature, pH, oxygen concentration, and material properties.
Mechanism of Destructive Action of Chlorides on Metals
Stainless steel is resistant to corrosion due to a thin passive film on its surface. It contains chromium compounds and isolates the metal from aggressive environments. However, this film is not absolutely invulnerable: chloride ions can disrupt its stability at localized spots, creating conditions for corrosion to develop.
Pitting Corrosion of Stainless Steel and Pipelines
Pitting corrosion is localized destruction of metal forming small depressions that can gradually turn into deep cavities. The danger lies in the fact that a significant part of the pipe's surface can appear intact, while individual areas are already losing wall thickness.
The mechanism of the process is related to a local disturbance of the passive layer. At the site of the defect, the metal begins to dissolve, creating an anodic area, while cathodic reactions occur on the neighboring surface. Inside the pit, corrosion products accumulate, the chemical composition of the environment changes, and acidity may increase. Chloride ions support this process and complicate the reformation of the protective film.
The risk increases with rising temperature and chloride concentration, as well as with the presence of gaps, deposits, and stagnant zones. The consequences are localized leaks, contamination of the product with corrosive particles, emergency repairs, and unplanned production stoppages.
Therefore, the impact of chlorides on pipes should be assessed considering the grade of steel and actual operating conditions. There is no universal safe concentration for all types of stainless steel.
How High Chloride Content Affects Reverse Osmosis Systems
Reverse osmosis is used to reduce the concentration of dissolved salts, including chlorides. The semi-permeable membrane allows water to pass while retaining a significant portion of dissolved ions. The effectiveness depends on the type of membrane, pressure, temperature, and the composition of the source water.
At the same time, increased concentrations of chlorides in the feed water raise osmotic pressure. To achieve the required productivity, a higher operating pressure may be needed, and due to the influence of chlorine on the pipes and improper design, energy costs and system load increase. Additionally, retained salts concentrate in the concentrate stream, so during design, the risk of deposit formation and corrosion compatibility of components must be taken into account.
Reduction of Membrane and Seal Lifespan
The effect of chlorides on osmosis should be considered separately from the effect of free chlorine. Chloride ions are dissolved salts that the membrane must retain. Free chlorine and other oxidizers can chemically damage the polyamide selective layer of the RO membrane, resulting in reduced salt retention and changes in performance.
Residual free chlorine must be removed before contacting the polyamide membrane; this is done using activated carbon or suitable chemical reducers. The condition of the seals also depends on the material, temperature, and compatibility with the specific environment, so their lifespan is assessed based on operating conditions, not just chloride concentration.
Effective Methods for Cleaning Water from Chlorides
To choose a technology, first, the concentration of chlorides is determined through laboratory analysis, and a target indicator for the production process is established. If it is necessary to reduce the overall concentration of dissolved salts, reverse osmosis is needed. In special cases, electrodialysis and other desalination technologies may also be used.
Why Standard Filters Do Not Retain Chloride Ions
Mechanical filters retain particles by size, while ordinary carbon filters are primarily designed for removing free chlorine, organic compounds, and substances that affect odor and taste. Dissolved chloride ions are much smaller than the pores of such filters and remain in the water.
Softeners also do not solve the task of completely removing chlorides: they replace calcium and magnesium ions with other ions, but do not provide overall desalination. Therefore, for substantial reduction of chloride content, membrane technology is usually required, tailored according to the water analysis results.
Invent Group offers engineering solutions for water treatment that are tailored to the composition of the source water and the requirements of specific production.
For food and chemical industry enterprises, monitoring chlorides is not only a quality water issue but also a way to reduce the risk of localized corrosion, leaks, and expensive downtimes. Regular water analysis helps assess the danger to metal surfaces, and properly selected desalination reduces the concentration of aggressive ions in the technological flow.